800208RPM-9000C4
Description:
Portable Multi-parameterPatient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP.It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient.
Features:
12"high resolution color TFT LCD display.
6 Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, PR.
Can be arbitrarily set the alarm limit, automatic sound and light alarm.
The back of the machine is designed with a storage box, which can put some accessories,convenientfor doctors use.
Drug solubility calculation function, Arrhythmia analysis function.
Built-in lithium battery,AC and DC,can provide long-term monitoring after power failure.
Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center,ICU,CCU.
Specification:
ECG
Lead Mode:5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection:I, II, III, avR, avL, avF, V,
Waveform:2 ch
Lead mode:3 Leads ( R, L, F or RA, LA, LL)
Lead selection:I, II, III,
Waveform:1 ch
Gain:´2.5mm/mV,´5.0mm/mV,´10mm/mV,´20mm/mV, auto
HR and Alarm
Range:
Adult:15 ~ 300 bpm
Neo/Ped:15 ~ 350 bpm
Accuracy:± 1% or ± 1bpm,which great
Resolution:1 bpm
Sensitivity:> 200 (uV P-P)
Differential Input Impedance:> 5 MΩ
RESPARATION:
Method:Impedance between R-F(RA-LL)
Differential Input Impedance:>2.5 MΩ
Measuring Impedance Range:0.3~5.0Ω
Base line Impedance Range:0 – 2.5 KΩ
Bandwidth:0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult:0 ~ 120 rpm
Neo/Ped:0 ~ 150 rpm
Resolution:1 rpm
Accuracy:±2 rpm
Apean Alarm:10 ~ 40 S
NIBP
Method:Oscillometric
Mode:Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode:5 Min
Pulse Rate Range:40 ~ 240 bpm
Alarm Type:SYS, DIA, MEAN
Measuring and alarm range:
Adult Mode
SYS:40 ~ 270 mmHg
DIA:10 ~ 215 mmHg
MEAN:20 ~ 235 mmHg
Pediatric Mode
SYS:40 ~ 200 mmHg
DIA:10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS:40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Overpressure Protection
Adult Mode:297±3 mmHg
Pediatric Mode:240±3 mmHg
Neonatal Mode:147±3 mmHg
SpO2
Measuring Range:0 ~ 100 %
Alarm Range:0 ~ 100 %
Resolution:1 %
Accuracy:
70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval:about 1 Sec.
Alarm Delay:10 Sec.
Pulse Rate
Measuring and Alarm Range:0~254bpm
Resolution:1bpm
Accuracy:±2bpm
I.5TEMP measurement:
Channel:1
Measuring and Alarm Range:0 ~ 50°C
Resolution:0.1°C
Accuracy:±0.1°C
Actualization interval:about 1 Sec.
Average Time Constant:< 10 Sec.
Package List:
1×Patient Monitor
1×EKG Lead wire
1×NIBP Cuff
1×NIBP Extension Cable
1×SpO2 Sensor
1×Temp Sensor
1×Ground Cable
5×Electrode
2×Fuse
1×User Manual(CD)
800205RPM-9000F
Description:
Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.
Features:
8 inch TFT color screen
Exquisite design suitable to moving operation
Various interfaces: standard screen, trend screen, oxyCRG screen, NIBP list screen, big front screen.
Real-time S-T segment analysis, pace-maker detection.
Built-in rechargeable lithium battery,convenient for patient moving.
Suitable for adult, pediatric and neonatal patient
Standard Configuration:
SpO2, PR, NIBP, ECG, RESP, TEMP
Technical Parameters:
ECG:
Lead Mode:5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection:I, II, III, avR, avL, avF, V,
Waveform:2 ch
Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
Heart Rate:15-300BPM(Adult) 15-350BPM(Neonatal)
Accuracy:± 1% or ± 1bpm,which great
Resolution:1 bpm
ST measurement Range:-2.0-+2.0mV
Sweep Speed:12.5 mm/s,25mm/s,50mm/s
Alarm:Available
Review:Available
RESP:
Method Impedance between R-F(RA-LL)
Measuring Range:Adult0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpm
Resolution:1 rpm
Accuracy:±2 rpm
NIBP:
Method:Oscillometric
Mode:Manual, Auto, STAT
Measuring and alarm range
Adult Mode
SYS:40 ~ 270 mmHg
DIA:10 ~ 215 mmHg
MEAN:20 ~ 235 mmHg
Pediatric Mode
SYS:40 ~ 200 mmHg
DIA:10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS:40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Resolution:1mmHg
Accuracy:+-5mmHg
SpO2:
Measuring Range:0 ~ 100 %
Alarm Range:0 ~ 100 %
Resolution:1 %
Accuracy:70% ~ 100% ±2 %
Actualization interval:about 1 Sec.
Alarm Delay:10 Sec.
Pulse Rate :0~254bpm
Resolution:1bpm
Accuracy:±2bpm
Temperature:
Measuring and Alarm Range:0 ~ 50 C
Resolution:0.1C
Accuracy:0.1C
Actualization interval:about 1 Sec.
Average Time Constant:< 10 Sec.
Package List:
Patient monitor
Temperature probe
ECG lead cable
ECG electrode
Adult NIBP cuff
NIBP extension tube
Adult fingertip SpO2 probe
Power cord
User Manual
800204RPM-9000D3
Description:
Dental Oralimplantmonitor can be used in oral implant surgery. It can monitor and measure human bodys vital signs in real time for patients, especially patients with cardiovascular and cerebrovascular diseases and diabetes, and monitor the changes of life signs in real time, and provide basis for oral implant.
Features:
High brightness and high resolution display 8 inch color LCD screen ,more comfortable glare
7-Channel ECG Waveform display,5 minutes ECG waveform playback, automatic detection of ST segment
384 hours trend data memory for all the parameters and dynamic waveform capture
Can be arbitrarily set the alarm limit, automatic sound and light alarm
Anti-movement, anti-defibrillation, anti electrosurgical interference
Remote central monitoring network interface
Drug solubility calculation function, Arrhythmia analysis function
Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure
Widely used in the Department of internal medicine,Dntal practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.
Standard configuration:
ECG, NIBP, SPO2, TEMP, RESP,
Technical parameters:
ECG Measurement:
Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed
Gains options: × 1, × 2, × 4, and × 0.5 four trenches
Frequency:
diagnosis 0.05 ~ 130Hz
Monitoring 0.5 ~ 40Hz
Operation 1~ 20Hz
Common-mode signal inhibition:
diagnosis > 90 dB
Monitoring > 100 dB
Operation > 100 dB
Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.
HR range:
Adult :15~300bpm
Infants / children: 15~350 bpm
HR Accuracy: ± 1 bpm
Precision calibration signal: 1mv(peak, ± 5% accuracy)
ST Detection: measurement range (-2.0mV~+2.0mV)
Baseline recovery time: < 3 seconds after defibrillation
Alarm: Sound and Light
Preset heart rate range: (Alarm over preset numerical)
Ceiling:40~255 bpm adjustable
Threshold: 20~160 bpm adjustable
RESP Breath:
Breathing frequency range:
Adult : 7~120 brPM
Infants / children:7~150 brPM
Accuracy:± 2brpm
Gains options: × 1, × 2, × 4, and × 0.5 four trenches
Alarm: Sound and Light
Alarm range: (numerical preset alarm over)
Ceiling: 10~100 bpm adjustable
Threshold: 0~99 bpm adjustable
NIBP measurement:
Technology: Oscillometric
Mode: Manual / automatic / continuous
Measurement units: mmHg / kpa
Protection: Double security protection
Scope: Pressure Cuffs 0-250 mmHg
Overvoltage protection: Double safety protection
Adult Pattern:300 mmHg
Children Pattern:240 mmHg
Newborn Pattern:150 mmHg
Blood pressure measuring range:
Adult
Systolic blood pressure: 40~270 mmHg
Diastolic blood pressure: 10~215 mmHg
Pressure on the average: 20~235 mmHg
Children
Systolic blood pressure: 40~200 mmHg
Diastolic blood pressure: 10~150 mmHg
Pressure on the average: 20~165 mmHg
Newborn
Systolic blood pressure: 40~135 mmHg
Diastolic blood pressure: 10~100 mmHg
Pressure on the average: 20~110 mmHg
The accuracy of blood pressure:The maximum average error amp 5mmHg; maximum standard deviation 8mmHg
Alarm: Sound and Light
Preset range: report (Numerical exceed preset alarm)
Systolic blood pressure maximum: 40~250 mmHg adjustable
Threshold: 10~220 mmHg adjustable
Diastolic blood pressure ceiling: 20~250 mmHg adjustable
Minimum standards: 10~220 mmHg adjustable
Spo2 measurement
Range: 70~00%:±2DIGIT 0~69%:Not defined
Resolution: 1%
Pulse frequency: 20~300 times / min
Alarm: Sound and Light
Preset range: report (Alarm over preset numerical)
Ceiling: 20%~100% adjustable
Threshold: 10%~99% adjustable
TEMP measurement:
Technology: thermostat temperature probe
Measuring range: 0°C~45°C
Temperature resolution: 0.1%
Accuracy: ± 1°C
Response Time: 1s
Alarm: Sound and Light
Preset range: report (numerical preset alarm over)
Maximum: 20.1°C~45°C adjustable
Threshold: 20°C~44.9°C Adjustable
Power:
AC power supply: AC 220V, 50Hz. 1A maximum current
Temperature: 5~40°C
Storage temperature: -20°C~40°C
Working humidity:≤85% relative humidity, non-condensing
Humidity storage:≤95% relative humidity, non-condensing
Altitude: 86~4106kpa feet (working condition)
Whole Power: not more than 70VA
Package Include:
1×Dental Patient Monitor
1×Cuff for adult
1×SpO2 Probe
1×5 lead EKGCable
1×Temperature Probe For ECG monitor
Payment
We accept PayPal only. We will ship out the item after receiving cleared payment.
Shipping
A complete and correct shipping address is essential.
Customers with shipping addresses outside of the U.S. are responsible for all duties and import taxes. Please contact your customs for information
Return Policy
All items are in brand new condition unless specified.
FDA declaration
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser.If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.All of our products are CE approved. Please kindly check the copy of the certificate in the listing below.(Leezoe-China-Beijing-86-15963302815)
This item has been cleaned and treated according to the manufacturers instructions.
510(K)Number: K161892
Contact Us
Any questions, please contact us through eBay message or e-mail, We will reply within 1-2 business days (public holidays not included).
working time: Monday - Friday 9:00 AM - 5:30PM (Beijing)
1×User Manual